Had a fault on a GivEnergy AC coupled 3kW home battery and was getting no joy from multiple companies I contacted, as well as the original installer. Contacted Solar Tech Support and they sorted it really quickly, now working perfectly again, can’t recommend them highly enough, professional and very responsive!
LuxPowerTek Fault Code Index
- Sourced from official LuxPowerTek manuals
- Covers hybrid and off-grid inverter series
- E-codes (errors) and W-codes (warnings)
If your Lux inverter is showing an error or warning code and you need expert diagnosis, a remote diagnostic identifies the cause and recommends the fix — usually within 30 minutes.
Book free Lux diagnosisHow diagnostics workI've spoken to Ron a couple of times with issues with my Givenergy installation. Such a friendly knowledge guy very highly recommended. Thank you very much for resolving my issues
Ron want out of is way to help, nothing was to much. He was very thorough in what he did Very knowledgeable I would highly recommend Ron and his company He did a fantastic job for me. if you have any problems, he'll do his best to help you out and resolve your problem. I wouldn't hesitate to recommend them
Ronald was able to organise a brilliant electrician with extensive experience of GivEnergy systems local to me in the SW. I have now got a fully functioning system and suspect that my electricity bill will be substantially reduced or in credit over a year. Also when said electrician discovered an overvoltage in the my local grid, Ronald prepared a very lucid and comprehensive report of the situation which I have now supplied to my local grid. Cannot recommend Ron and Dan enough.
Contacted Solar Tech about my Givenergy battery storage system that wasn't working. Battery status was "idle". Given the company Givenergy had gone bust, I need independent quality technical help. Very patient and clearly very knowledgeable about battery systems Ron diagnosed possible issues and suggested several possible remedies. Worked our way through them and fortunately it began to work. The fault was very specific and only an experienced engineer would have thought to check. Suffice to say I'll be back if I need independent support again. Lastly you only pay if there is a solution. Outstanding.
Made contact for assistance with my GiveEnergy battery that wasn't discharging. Ronald looked at my issue the same day, identified the root cause with a clear explanation of what was going on along with some options on how to remediate the issue. So far my battery is now working and keeping my fingers crossed that it stays this way. Ronald is a very experienced and knowledgeable engineer and I would recommend.
Faults and warnings triggered by problems with the AC mains supply, grid voltage, grid frequency, or meter connections. Warning codes self-clear when conditions normalise; error codes stop the inverter.
E023 — Neutral faultLCD: E023 · LXP hybrid seriesW016 — No AC connectionLCD: No AC connection · LXP hybridW017 — AC voltage out of rangeLCD: AC V Outrange · LXP hybridW018 — AC frequency out of rangeLCD: AC F Outrange · LXP hybridW030 — Meter connection reversedLCD: Meter Reversed · LXP hybridFault codes caused by problems with the solar panel DC input — overvoltage, short circuits, and insulation failures. PV voltage errors are serious and may indicate an unsafe string configuration.
E021 — PV voltage high Do not touch DC cablingE024 — Both PV short circuit Disconnect PV at DC isolatorW020 — PV isolation lowLCD: PV Isolation low · LXP hybridW023 — PV short circuitLCD: PV short · LXP hybridCodes related to battery communication, voltage limits, temperature sensors, and hardware failures. W000 (battery communication fault) is the most common Lux warning in UK installations.
E002 — Bat On Mos Fail Hardware fault — SNA seriesW000 — Battery communication faultLCD: Bat Com Fault · all seriesW003 — Meter communication faultLCD: Meter Com Fault · LXP hybridW004 — Battery failureLCD: Battery failure · all seriesW025 — Battery voltage highLCD: Bat Volt High · all seriesW026 — Battery voltage lowLCD: Bat Volt Low · all seriesW027 — Battery open circuitLCD: Bat open · all seriesFaults on the backup power (UPS/EPS) output — short circuits, overloads, and wiring errors. These codes appear when the backed-up circuit has an issue.
E012 — UPS short circuit Disconnect loads immediatelyE013 — UPS power reversed Wiring fault — qualified electricianE020 — UPS connection faultLCD: E020 · all seriesW028 — UPS over loadLCD: UPS Over Load · all seriesError codes specific to multi-inverter parallel installations. These only appear when two or more Lux inverters are connected via CAN bus in a parallel configuration. Single-inverter systems will never show these codes.
E001 — Model faultLCD: E001 · parallel config errorE008 — Parallel CAN faultLCD: E008 · CAN bus failureE009 — Primary lossLCD: E009 · master inverter missingE010 — Multiple PrimaryLCD: E010 · duplicate master configE011 — Parallel AC inconsistentLCD: E011 · AC mismatchE015 — Parallel phase abnormalLCD: E015 · three-phase assignmentInternal processor communication failures, relay faults, overcurrent, overtemperature, and bus voltage errors. Most require a restart as a first step — persistent codes typically indicate hardware failure.
E000 — Internal communication fault 1LCD: E000 · DSP comm failureE016 — Relay fault Safety isolation — do not bypassE019 — Bus voltage highLCD: E019 · DC bus overvoltageE022 — Over currentLCD: E022 · internal overcurrentE025 — Temperature over rangeLCD: E025 · overtemperature shutdownE026 — Internal faultLCD: E026 · general hardware faultE027 — Sampling inconsistentLCD: E027 · LXP hybrid onlyE031 — Internal communication fault 4LCD: E031 · DSP comm failure variantW005 — Auto Test failureLCD: Auto Test failure · LXP hybridW009 — Fan StuckLCD: Fan Stuck · SNA off-gridW021 — Leakage current highLCD: Leakage I high · LXP hybridW022 — DC injection highLCD: DC Injection high · LXP hybridLuxPowerTek add new fault codes with firmware updates, and some codes are specific to newer GEN series models not covered in the original LXP and SNA manuals. If your code isn't listed, share the exact text from the inverter LCD or Luxpower View alarm log and we'll identify it.
Full diagnostic — CAN/RS485 cable, battery brand setting, DIP switches, and firmware compatibility.
Timer settings, Agile mode, force charge, and Luxpower View configuration.
Official LXP and SNA user manuals, wiring diagrams, and quick-start guides.
LuxPowerTek fault code questions
Got an error code and need it diagnosed?
Share the exact fault code from the inverter LCD or Luxpower View, describe what the system is doing, and when the fault first appeared. We'll identify the cause and tell you whether it needs a remote settings fix or a site visit.