Fronius State Code Alarm — Inverter Error Codes Explained
- Not affiliated with Fronius
- No fix, no fee
- Covers all state code classes
A recurring state code means the underlying condition has not been resolved. We review your Solar.web event history remotely to identify the pattern, classify the fault, and recommend the right fix — before booking an unnecessary site visit.
Book your free remote diagnosticBack to Fronius hubIndependent — not affiliated with Fronius International.
I've spoken to Ron a couple of times with issues with my Givenergy installation. Such a friendly knowledge guy very highly recommended. Thank you very much for resolving my issues
When my GivEnergy battery started playing up it became basically useless and several companies I called said they couldn’t help. Solar Tech Support really knew their stuff, communicated very well and resolved the problem quickly. Without them I’d have had to buy a replacement battery.
Solar Tech Support is an absolute lifesaver. My solar and battery system stopped working completely, but after one quick phone call, they fixed the problem straight away. The original provider, GivEnergy, has gone into administration, leaving me entirely without support from the original installers. It was a terrible situation on GivEnergy’s part, but thankfully, Solar Tech Support came to the rescue!
My Givenergy battery stopped working nearly a month ago. After unsuccessfully reaching out to my installer, who looks like he's also busted, I found Solar Tech Support on a Google search. They fixed my issue in a couple of hours. Any frustrated Givenergy customers, I highly recommend these guys.
Ron was really helpful. He remotely adjusted my battery settings on the same day I contacted him, and at a reasonable price. Great service.
6-step state code diagnosis
Work through these steps to identify what your Fronius state code means, whether it needs action, and what that action should be.
Find the state code on your inverter or Solar.web
Fronius state codes appear in two places. On the inverter itself, the LCD display shows the current state code number and a short description. In Solar.web — Fronius's monitoring portal — the event log records every state code with a timestamp, so you can see exactly when each event occurred and how long it lasted.
Open Solar.web, navigate to your system, and check the event log. Write down the exact code number and when it first appeared. If the inverter display is showing a code but the system is still producing power, that is a Class 3 informational code. If production has stopped entirely, the code is more likely Class 1 (grid) or Class 4 (hardware).
Identify the code class from the first digit
The first digit of the state code tells you the severity and whether you need to act:
Check whether the code is temporary or persistent
Open the Solar.web event log and look at the pattern over time. A code that appeared once during a grid disturbance and cleared on its own is temporary — no action needed. A code that appears every day at the same time, such as state 102 every sunny afternoon, points to a recurring grid overvoltage issue that may need investigation.
State 306 and 307 appearing only at dawn and dusk are completely normal — they indicate insufficient light for feed-in. A Class 4xx code that persists after a restart is a hardware fault. The key question is whether the code is reducing your energy production during the hours when the system should be generating.
Try a manual reset for non-hardware codes
For Class 1xx and 5xx codes, pressing the button on the inverter display clears the alarm and lets the inverter attempt reconnection. For a full power cycle:
If the code returns immediately after restart, do not keep cycling the power. The fault is persistent and needs professional diagnosis. Class 4xx codes that return after a reset confirm a genuine hardware problem.
Review the Solar.web event history for patterns
The most useful diagnostic information is the pattern over time. Check the event log covering at least the last 30 days and look for correlations:
This event history is exactly what a diagnostic engineer needs to identify the root cause remotely — without an unnecessary site visit.
Book a diagnostic if the code keeps returning
If a state code is recurring and affecting your energy production, it needs professional diagnosis. STS reviews your Solar.web event log and production data remotely to identify whether the issue is grid-related, weather-related, or a hardware fault — before anyone visits the property.
For grid overvoltage issues (state 102), the solution may involve contacting your Distribution Network Operator. For hardware faults (4xx), the engineer can identify the likely component before attending site — reducing diagnosis time and cost.
Why state code 102 is increasingly common across the UK
State 102 — AC voltage too high — is the most common recurring Fronius state code in the UK. The inverter disconnects because it has measured grid voltage above the safe threshold, typically above 253 volts on the UK nominal 230V supply. It reconnects automatically when the voltage drops, but if this happens repeatedly during peak sun hours, the system loses significant generation.
The underlying cause is grid infrastructure that was not designed for widespread solar export. On rural and suburban networks with multiple solar installations, simultaneous export during midday pushes the local voltage upward. The houses furthest from the transformer see the highest voltage and are the first to trip. This is a network issue, not an inverter fault — reporting it to the Distribution Network Operator is the correct next step, as they may need to adjust the transformer tap or reinforce the local network.
Fronius inverters operating under G98/G99 grid codes in the UK have specific voltage and frequency trip settings. In some cases, an installer can adjust the voltage threshold within the allowed range to reduce nuisance tripping — but this must be done by a qualified person with access to the inverter service menu and only within the parameters permitted by the grid code.
Most common Fronius state codes in the UK
Grid voltage exceeds the safe limit. Common on networks with high solar penetration. Auto-reconnects when voltage drops. Report to DNO if it happens daily.
Insufficient DC power or voltage to feed in. Normal at dawn and dusk. Only a concern if it appears during peak sun hours — check for panel shading, soiling, or a DC wiring issue.
Heat sink temperature sensor has failed or disconnected. Hardware fault — try a power cycle first. If it returns after restart, the inverter needs professional repair.
The system has not generated for a full day. Check for snow, heavy soiling, or a tripped AC breaker before assuming a fault. If panels are clean and breakers are on, the inverter needs investigation.
DC insulation resistance has dropped below the safe threshold. Almost always caused by water ingress. Do not restart — see our dedicated isolation fault guide.
State code alarms — common questions
Recurring state code? We find the cause remotely.
We review your Solar.web event history and production data to identify whether the issue is grid-related, weather-related, or a hardware fault — before booking a site visit.
- Not affiliated with Fronius
- No fix, no fee
- Covers all Fronius state code classes
We use cookies to measure traffic and improve our ads — including sharing limited, hashed details with Meta (Facebook) to measure ad performance. Accept, or decline for essential cookies only. Privacy policy
Got a solar fault or need a quick answer? Drop us a message — we usually reply within a few minutes. Mon–Fri, 9am–7pm.