After GivEnergy went into liquidation, just my luck, my battery started playing up (internal board crashed). Contacted my installer - not interested! Found Solar tech support on a Google search. Sooo glad I found this company! Ron is extremely helpful and has plenty of experience. He soon confirmed what the fault was, and helped me to get my system up and running again. Now moved my GivEnergy account to Solar tech support, and will definitely use again if I have more issues. Unusual to find such a helpful company in these times, no morons reading scripts, just direct contact with the engineer.
Growatt Error 117 — Relay Fault
- Growatt-documented relay fault
- One restart, then a warranty claim
- Legacy TL, MTL, MTL-S and UE families
One restart is Growatt's first step. If Error 117 returns after it, the relay or its circuit has failed and Growatt's own remedy is a replacement inverter under warranty. We read your ShineServer log and tell you which of the two you are in.
Book your free remote diagnosticError 04 (the safety fault)Growatt documents Error 117 as a relay fault: the relay check has failed six times.
I have a GivEnergy system consisting of two batteries, two inverters and a controlling EMS (Energy Management System) which has not worked since Nov 2025. After six months I discovered Solar Tech Support, reached out to them and Ron phoned me back – how often do you get that service? Could not be more helpful – worked directly with me over the phone, outside what I would call normal working hours. Lucid explanations and we were able to discuss the issues and history using camera and email history. As this was a very rare setup, Ron was able to access an EMS expert in the field to confirm the solution. One sunny day in, I am now only paying for standing charge and a few pence for spikes in grid consumption while battery catches up with house demand.
STS installed/commissioned an extra Givenergy battery for me. Communication was great and the engineer did a great job and even tidied up the existing wiring which made it look a great deal nicer than it did. Very happy so far and grateful to the team for their professionalism.
Givenergy panels and battery had been offline for a couple of months after various changes by Givenergy to their app etc. Ron did a fantastic job of sorting it out - got things up and running almost immediately, followed by some fine tuning to get things fully configured. What a legend - great service, great comms, great result.
Big thanks to Ron. He was incredibly patient and helpful over the phone, taking the time to walk myself and the installer through every troubleshooting step. Through lots of testing he figured out the issue was definitely a hardware issue, which allows us to consider our next steps. Support fees are clear and they operate a “no fix no fee” policy. It is rare to find that kind of honesty combined with dedicated phone support nowadays. I highly recommend Ron, if you need help with your solar system don’t hesitate to give him a call.
Genius when it comes to solar and off grid installations we spent days trying to work out what was causing our problems and Ron resolved it in less than an hour! Cant reccomend enough
5-step diagnostic process
Work through these in order. Growatt allows one restart. After that, Error 117 is a hardware matter, not a setting.
Confirm the code and check which Growatt family your inverter is
Read the exact code on the inverter display or in ShineServer Fault Logs, and note when it first appeared. Growatt documents Error 117 as a relay fault on its legacy grid-tie families: TL and MTL, MTL-S, and the 10-20kUE three-phase range. On MIN TL-X and MOD TL3-X inverters the relay fault is Error 405 instead, so check the model on the inverter label before matching a code.
Restart the inverter once
Growatt's documented first step is to restart the inverter. Switch off the AC supply at the consumer unit, then the DC isolator, wait a few minutes, and restore in reverse order. Do not open the inverter. If the code clears and stays clear, no further action is needed.
Record whether the code comes back
Growatt's instruction is explicit: if the error still exists after a restart, contact Growatt service to replace the inverter. Note the date and time of every Error 117 in the ShineServer fault log. A code that returns is a hardware fault in the relay or its circuit, not a setting, so repeated power-cycling is not the fix.
Find the install date and serial number for the warranty claim
An Error 117 that survives a restart is a warranty matter. Find the install date and the inverter serial number from your handover pack or the label on the side of the inverter.
Note the firmware version before you raise the claim
Growatt service will ask for it. Check the current firmware version in ShineServer (Device → Info → Firmware Version) and note it alongside the model and serial number. Growatt does not list a firmware remedy for 117. The documented remedy is the restart and then the replacement. The version is still part of the information a claim needs.
Request a remote session if you want the claim evidenced
If the code keeps returning, we can review your ShineServer fault history, confirm how often Error 117 has been raised and what the inverter did each time, and give you a written summary to send to Growatt or your installer. The replacement itself is arranged through Growatt or the original installer.
Where you'll see Error 117
Inverter screen shows "Error 117" with amber/orange LED. Generation stops. The inverter re-runs the relay check when it restarts.
Log into ShineServer → Device → History. Error 117 appears with a timestamp. Note every occurrence. A repeat is what turns this into a warranty claim.
Error history tab shows Error 117 entries with dates and times.
Affected Growatt models
TL and MTL series — Growatt's legacy grid-tie numbering, where Error 117 is documented
MTL-S series — same 1xx error scheme
10-20kUE three-phase — listed as "Relay fault, relay check fails 6 times" in Growatt's UE troubleshooting guide
On MIN TL-X and MOD TL3-X the relay fault is Error 405, not 117. On MIN TL-XH and SPH the scheme uses 3xx and 4xx codes alongside named messages.
What you should know about Error 117
Growatt's troubleshooting documents give it as "Relay fault, relay check fails 6 times", and say there is something wrong with the relay or its relevant circuit.
Growatt's remedy is: restart the inverter; if the error still exists, contact Growatt service to replace the inverter. Repeated resetting is not the fix.
It is the component that connects and disconnects your system from the grid, and the inverter checks it before connecting. That is why a check that keeps failing stops generation.
Growatt New Energy warns that some error codes indicate a fatal error and require the supplier or Growatt to replace the unit. Keep the ShineServer fault log as evidence.
About Growatt Error 117
Error 117 belongs to Growatt's legacy grid-tie error scheme, used on the TL and MTL, MTL-S and 10-20kUE families. Growatt's own troubleshooting documents give it as "Relay fault, relay check fails 6 times", and explain that there is something wrong with the relay or its relevant circuit. The inverter stops generating.
The remedy Growatt publishes is short: restart the inverter, and if the error still exists, contact Growatt service to replace the inverter. There is no setting to change. If your inverter is a MIN TL-X or MOD TL3-X, the relay fault you are looking for is Error 405, not 117.
Error 117 questions answered
Error 117 affecting your system?
Tell us how often Error 117 is occurring. We'll review your ShineServer fault history to confirm whether the restart held or the relay check is still failing, and give you a written summary for the warranty claim.
- Not affiliated with Growatt Technology Co. Ltd
- No fix, no fee
- Most cases resolved without site visit
We’re busier than ever. Thank you for your patience.
Due to unprecedented demand we’re currently only carrying out on-site work in Yorkshire, and replies are taking up to 7 days. Remote diagnostics continue for the whole UK as normal.
Every message is read and answered, so please don’t send it twice; that only slows the queue.
We use cookies to measure traffic and ads, sharing limited hashed data with Meta and Google. Decline keeps only essential cookies. Privacy policy
Got a solar fault or need a quick answer? Drop us a message and we usually reply within a few minutes. Mon–Fri, 9am–7pm.