Ron is a life saver sorted out a connectivity problem and had to replace one of my inverters all good now so I can stop stressing. Thank you again
Fox ESS Meter Lost Fault or CT not detected
- All Fox ESS models
- No fix, no fee
- Not affiliated with or endorsed by Fox ESS
Send us the alarm's exact words and number, the date and time it first appeared, and anything that changed shortly before, such as a firmware update. With your permission we review your Fox Cloud alarm history, settings and firmware version.
Book your free remote diagnosticFox ESS hubIndependent, not affiliated with or endorsed by Fox ESS.
When my GivEnergy system had an issue, I was completely left without support and had honestly lost all hope. Thankfully, I searched online and found Ron, which completely turned things around. After sending him a message, he responded incredibly fast and called me to assure me that he would get the problem fixed. I really admire his dedicated, supportive nature and his determination to find a solution. With this kind of outstanding attitude and customer service, he has absolutely secured a future customer in me.
A really big thank you to Ron and his team, he has vast amounts of knowledge and got my system back up and running, also good to get on with. I was absolutely lost as to know what to do, no help from installer and somehow came across Ron and am I glad I did. I would definitely definitely recommend him to anyone who has faults with there solar system, any make I would say. Thanks again Ron a pleasure meeting you.
⭐⭐⭐⭐⭐ 5-Star Review – Solar Tech Support Installing solar panels is only the first step! To get the best possible performance and maximise your investment, you need to make sure your system is configured correctly and all settings are properly optimised. **Solar Tech Support did exactly that for me, and I couldn't be happier with their professional service!** Their knowledge, expertise, and attention to detail helped me optimise my solar system to get the most out of it. If you already have solar panels and battery storage, I highly recommend contacting Solar Tech Support for professional advice, system optimisation, and technical support. Don't just install solar panels – make sure you're getting the maximum benefit from your investment! ⭐⭐⭐⭐⭐ Highly recommended! Thank you, Solar Tech Support, for your excellent service!
Ron was extremely helpful and tried his best to repair/reset our GivEnergy inverter remotely. In the event he was unsuccessful but he couldn’t have been more helpful. If you have problems with a GivEnergy system please contact him. Highly recommended
As a Givenergy customer I have been forced to get familiar with my system since it developed battery failure. I managed to find someone to repair the battery and managed to do the physical install and connection. I reached out to Ron at Solar Tech Support and with the help of whatsapp and many screenshots of the system, cloud and App Ron managed to get me through getting it all up and running. Big thanks to Ron.👏👏
What Fox's meter and CT alarms mean
A CT clamp, or a Fox meter (a Chint DDSU666 or DTSU666), on your incoming grid supply tells the inverter what is going to and from the grid. Fox's H1-G2 and EVO10 come with a CT in the box, and the H3/AC3 with a meter. Everything on this page is done in the Fox app (FoxCloud 2.0), on foxesscloud.com or by reading the inverter's own screen. Nothing here asks you to open a cover, touch a switch or move a cable.
Meter Lost Fault
Fox says communication between the meter and the inverter is interrupted. Owners report it as a communication fault between the inverter's manager and the meter. Fox's action is to check the cable between the meter and the inverter is correctly and securely connected. That cable runs to the inverter and the meter, so it's your installer's job.
CT or meter not detected
Code 240 means the CT or meter isn't detected, and a firmware mismatch after a battery change can cause it too. Owners quote it as "fail to detect CT". It isn't in the Fox user manuals we've read, so we have no Fox action for it. Owners report checking the CT, its cable and the Meter/CT setting, all installer checks. See our field note on a Fox ESS code 240 case.
A CT error on a system with no CT
Fox says a hybrid with no batteries and no CT must have its CT option switched off, or the inverter goes into an error state. The setting has to match what's fitted, and your installer checks it. See no CT fitted, or a setting that changed.
BMS Lost is a different alarm
Fox uses BMS Lost for a lost link between the inverter and the battery's management system, not the meter. See our BMS communication fault page.
About the numbers
Fox Cloud prints numbers, and one owner reports that the app's alarm history shows them. Fox's user manuals for the H1-G2, H3, KH and EVO10 list their alarms by name instead, so a number on its own won't lead you to the manual. Write down the words as well as the number.
If you have seen 1292, "Meter's CT line fault", quoted online, it comes from the manual for Fox's H3-Plus/P3-Plus, 50 to 125 kW commercial inverters. There the action is to check the meter's CT cables, and Fox doesn't say it is the same alarm as 240.
What you can check in the Fox app
Five checks, all on your phone or on foxesscloud.com. Note what you find, then send it to us or to your installer.
In FoxCloud 2.0, alarms sit under the bell icon at the top right, in Current and History lists. Older versions of Fox's app manual call the screen Faults, under Me. A moderator on Fox's Tech Hub forum said in late October 2026 that notifications aren't in the latest version of the app yet, so you have to look.
Note its exact words, its number if the app shows one, the date and time it first appeared, and whether it is still under Current or only in History.
The app's plant list sorts systems into Normal, Faulty and Offline. Offline means the datalogger has lost its internet link, and the system usually keeps running, so check the inverter's own screen. That's a different problem, covered on our Fox Cloud offline page.
Fox Cloud shows your solar, house load, grid and battery figures. The energy-flow screen refreshes every 3 to 5 minutes on most systems, or every 5 seconds on some newer models with recent firmware, so give it a few minutes. Note whether solar generation has dropped to zero while the alarm is current.
A firmware update, a battery added, a new meter or any other work on the system. Owners report 240 appearing after firmware updates, and a firmware mismatch after a battery change can cause it too. The app's Version section shows the inverter's firmware.
Then stop there. Leave the Meter/CT setting and the export limit to your installer or to us, because the right setting depends on what's fitted and Fox UK keeps export limitation for installer-level accounts. Don't open the inverter, the meter or the consumer unit to look at the CT clamp or its cable.
When the alarm can stop your solar
Some systems have an export limit. It's set on the inverter and caps how much power the inverter may send to the grid. On Fox's H1-G2 that limit works from the CT or meter. If the app shows the alarm and no solar generation, book help rather than wait for it to clear.
Fox's H1-G2 manual says that with an export hard limit set, losing the CT or meter communication makes the inverter disconnect from the grid and shut down. So on that set-up, a lost meter or CT link can stop your solar generating.
The same manual says a soft limit holds export below the set value within 15 seconds, but it doesn't say what happens if the link drops. None of the other Fox documents we read says what other set-ups do, so look at the solar figure in the app. On an owners' forum, one owner reported a 242 that stopped production for hours each afternoon, and the reply told them to call their installer.
No CT fitted, or a setting that changed
Which setting is right depends on what's fitted, so ask your installer, or us, to check it rather than change it yourself.
No CT fitted
Fox's single-phase CT guidance says a CT is compulsory on any installation with batteries. If a hybrid is installed with no batteries and no CT, its CT option has to be switched off, or the inverter goes into an error state. On the H1-G2 only one of the two is needed, a CT or a meter.
A setting that changed
Owners report the Meter/CT setting changing to disabled (in some reports after a firmware update) or to Meter on a system with a CT. In those reports, setting it back cleared the alarm. We found no Fox bulletin or official fix for a 240 after an update, and one owner's CT alarm stayed after Fox support restored the firmware.
Firmware after a battery change
A firmware mismatch after a battery change can cause a 240, as our Fox ESS code 240 field note shows. Tell us if a battery was added or swapped before the alarm first appeared.
Updating firmware
Fox's release notes say the H3 Smart's Manager firmware V1.24 (26 January 2026) improved meter and CT detection at low load. Owners can't update the inverter's firmware from their own Fox Cloud login: it needs an installer-level account, or a request to Fox ESS UK service with the inverter's serial number. Fox advises updating only when the system is stable, so an update isn't something to try while this alarm is showing.
Jobs for your installer
Fox writes its meter and CT checks for installers and qualified electricians. These are the checks owners swap on forums, and on a Fox system each one is your installer's job, or an engineer's on a site visit. Don't open the inverter, the meter or the consumer unit to look at any of these.
On single-phase systems the arrow on the CT points towards the grid. On the three-phase Chint DTSU666 meter, Fox says it faces the load. A CT fitted the wrong way round stops the H1-G2's export limit working.
Fox's guidance includes a resistance test on the CT, which your installer does. Fox supplies about 10 m of cable and allows up to 30 m. Beyond that it suggests a Modbus meter instead.
The meter talks to the inverter over an RS485 cable, and the pins it uses differ between models.
Fox's smart meter uses address 1 and 9600 baud.
Some single-phase Fox systems use Fox's wireless meter, and its install guide gives no guaranteed range. Fox says it isn't compliant with G100, the network operators' rules for export limitation schemes, so a wired CT or meter is used where an export limit has to meet G100.
The H1-G2 has a CT and meter self-test, run on the inverter's own screen with the battery and grid both connected. Fox's manual says remote access to it hasn't been developed yet.
Fox ESS can help too. In the app, Me > Contact Us lets you choose your system and send Fox a request. STS is independent, not affiliated with or endorsed by Fox ESS.
How we help with a Fox meter or CT alarm
We cover all Fox ESS models. With your permission, we use your login or an account transfer (£95) to review your Fox Cloud alarm history, settings and firmware version, and tell you whether we think it's a setting or the CT, the meter or the cable. The remote diagnostic is free.
If it's a setting we can change remotely, it's £125 only if we fix it remotely.
If the CT, the meter or the cable needs work, that's a site visit, from £295.
Questions about Fox ESS meter and CT alarms
Get help if your Fox ESS meter or CT alarm is still showing
Send us the alarm's exact words and number, when it first appeared, your inverter model and anything that changed shortly before. We cover all Fox ESS models. With your permission we review your Fox Cloud alarm history, settings and firmware version. Independent, not affiliated with or endorsed by Fox ESS.
- Not affiliated with or endorsed by Fox ESS
- No fix, no fee covers remote fixes. On-site work is quoted in writing before we start.
- On-site visits available
We’re busier than ever. Thank you for your patience.
Due to unprecedented demand we’re currently only carrying out on-site work in Yorkshire, and replies are taking up to 7 days. Remote diagnostics continue for the whole UK as normal.
Every message is read and answered, so please don’t send it twice; that only slows the queue.
We use cookies to measure traffic and ads, sharing limited hashed data with Meta and Google. Decline keeps only essential cookies. Privacy policy
Got a solar fault or need a quick answer? Drop us a message and we usually reply within a few minutes. Mon–Fri, 9am–7pm.