Error 04, Error 117, ShinePhone offline, isolation faults — we diagnose Growatt inverters at the engineering level. Remote-first using ShineServer data and fault code logs. Independent from Growatt and your original installer.

Not affiliated with Growatt Technology All MIC, MIN, MOD and SPH models supported Error code to root-cause diagnosis
Seeing a Growatt error code?

Error 04, Error 117, ShinePhone offline — we diagnose Growatt systems remotely in a single session.

Book Remote Diagnostic — from £75 → See the Solar Health Plan

Safety: If you have Error 04 (insulation fault), do not attempt to reset the system without identifying the cause — isolate at the DC switch.

Growatt Faults

Common Growatt problems we diagnose

Every fault below has a proven diagnostic path. Click through for the specific page or book a diagnostic if you're unsure.

Fault Codes

Growatt fault code index

Growatt error codes appear on the inverter LED display and in the ShinePhone app. Common codes: Error 04 (insulation failure), Error 117 (grid over-voltage), Error 107 (grid frequency out of range), Error 025 (DC bus voltage high). Share your exact code when you book — we identify the root cause as part of the remote diagnostic.

Fault code categories
·Isolation / DC faults — E0x series
·Grid faults — E1xx series
·AC & inverter faults
·Communication errors
Services

What we do for Growatt owners

Remote Growatt Diagnostic

We review ShineServer data, inverter settings, and fault history to identify the exact fault remotely.

Error code root-cause analysis
ShineServer data review
Settings validation
Book remote diagnostic →

Growatt System Recovery

Installer gone bust, ShineServer access lost, or monitoring never set up correctly? We recover access and rebuild documentation.

ShineServer access recovery
Monitoring reconfiguration
Warranty evidence pack
Start recovery →

On-Site Growatt Repair

Isolation fault investigation, DC cable fault location, CT clamp correction, component replacement.

Evidence-led targeted checks
Safety-focused report
Repair or replacement path
Discuss visit →
Documents

Growatt datasheets, manuals & warranty PDFs

Download datasheets, installation manuals and warranty documents for Growatt MIN, MID, MOD and SPH hybrid inverters. Self-hosted and always current.

📄Product datasheets & specifications
📘Installation & commissioning manuals
🛡Warranty terms & coverage documents
📱App & software setup guides
🔌Wiring diagrams
Fault Codes

Growatt fault code index

Seeing an error code on your Growatt inverter? Our fault code index explains what each code means, common causes, and safe next steps.

·Battery communication & BMS faults
·Grid connection & frequency faults
·Over-temperature & protection events
·WiFi & app connectivity errors

About Growatt systems — what you need to know

Growatt is one of the UK's most widely installed inverter brands — particularly popular with budget-conscious installers. The MIC, MIN, and MOD series cover residential string inverter installations. The SPH and SPA series are hybrid inverters with battery integration capability. All Growatt inverters display fault codes numerically on the front LED panel and report them to the ShineServer cloud via the ShineWiFi or ShineLink logger. Growatt's ShinePhone app provides remote monitoring and fault history access.

The most common Growatt searches we handle are: Growatt Error 04, Growatt Error 117, Growatt ShinePhone offline, Growatt not producing, and Growatt isolation fault. Error 04 is particularly common in older installations where panel connectors or cable insulation have degraded — it is a genuine safety event, not a nuisance fault. STS provides independent Growatt support across the UK — not affiliated with Growatt Technology Co. Ltd.

FAQs

Growatt questions answered

Error 04 on a Growatt inverter is an insulation resistance failure. The inverter has detected that the DC isolation between the solar panels and ground has dropped below the safe threshold (1MΩ). It is a safety protection — the inverter will not run until the fault is cleared. Causes include a faulty panel, damaged DC cable, or water ingress into a connector or junction box. Book a diagnostic — we'll identify the source of the fault remotely in most cases.

Error 117 is a grid over-voltage protection trip. The AC voltage at the inverter terminals has exceeded the G98/G99 limit (typically 253V in the UK). This is common in areas with dense solar installations where solar export raises the local grid voltage. The inverter disconnects to protect the grid. We can configure export limiting to prevent repeat trips, or notify the DNO if grid reinforcement is needed.

Causes include: the WiFi logger (ShineWiFi or ShineLink) losing its connection, the router password changed, ShineServer cloud-side outage, or the logger hardware has failed. The inverter may still be generating even when the app shows offline — see the ShinePhone offline fault card above for diagnostic steps.

No. Error 04 means the system has detected a reduction in electrical isolation between the PV panels and earth. Running through this fault risks electric shock. The inverter shuts down as a safety measure. Do not override it — identify and fix the cause first. Isolate the system and book an inspection — we assess remotely where possible.

We also support

STS supports all major inverter and battery brands — not just Growatt. If you have a mixed-brand system or are comparing options, visit the brand hub.

Browse all 19 brands →
Book

Ready to fix your Growatt system?

Tell us what's happening. We'll review your details and come back with a clear diagnosis path — usually same day.

Not affiliated with Growatt Technology Co. Ltd
Remote diagnosis from £75
On-site visits available across Yorkshire

By submitting you agree to be contacted about your request. Not affiliated with Growatt Technology Co. Ltd.