Called back within a day and gave good advice.
Fox ESS Support — Grid Faults, Battery Comms & EPS
- Not affiliated with or endorsed by Fox ESS
- All Fox ESS models
- Current and older batteries
Battery alarm, grid fault, EPS not working: we diagnose Fox ESS systems remotely in a single session. Fox Cloud offline? Follow our Fox Cloud offline guide, and if the datalogger needs reconnecting to your WiFi, we can set it up on site, from £195.
Book your free remote diagnosticFox Cloud offline guideSafety: do not open inverter or battery enclosures. Smoke, fire or a burning smell? Do not go near the equipment. Get everyone out, call 999 and tell them there is a solar battery.
Great service. Got our Givenergy battery back online remotely when others said it needed an onsite visit. Ron resolved the issue within about an hour of my email. Brilliant service.
Diligent and reliable service.
My 3-year old GivEnergy Solar/Inverter/Batteries installation went down with all generated electricity going to the grid and absolutely no help available from the Administrators! Thankfully, I found Solar Tech Support and Ron, who used to be a GivEnergy installer. His knowledge and ability are phenomenal and he sorted everything out remotely. I cannot recommend him more highly and a really pleasant guy to deal with! Very many thanks Ron!!
Ron was Absolute God send . After 6 months of nightmares with the installer who messed up in every single aspect of the install... Ron came investigate and provide me with a detailed report and standing behind his words for my case His knowledge and understanding are simply exceptional. I can not express how happy I am to have the luck to deal with him
I contacted Solar Tech Support because I had a problem with my legacy GiveEnergy installation. within 24 hours they had diagnosed the problem and offered advice on resolution. Because they were unable to fix the problem there was no charge! This despite numerous time consuming emails. I am currently trying to engage with the original installer but if that is unsuccessful I will go back to Solar Tech Support and ask them to repair the system with a retrofit. Very knowledgeable and responsive. I highly recommend them.
Fox ESS problems we diagnose
Pick the fault that matches what you're seeing for its guide, or book a diagnostic if you're unsure.
The inverter has raised a grid alarm because the voltage or frequency it measured was outside its allowed range, or the supply was lost. A wrong country setting, which the installer checks at start-up, is one possible cause and a high or weak supply is another. G98 applies to a system of up to 16 A per phase of total registered capacity (3.68 kW single-phase), and G99 applies above that, with an application to the network operator before installing.
See diagnostic guideInverter powered but generating no power. It could be a solar-side fault, a DC isolator switched off or a grid alarm. Check the Fox Cloud app and the inverter display for the alarm name before anything else.
See diagnostic guideInverter generating below expected output. It may be a solar-side problem, soiled panels or a settings fault. We review Fox Cloud historical inverter data by date (PV power, battery power, load and grid) to identify loss patterns.
See diagnostic guideGround Fault is an earth alarm and Iso Fault is a solar-side insulation alarm, and Bms Insul Fault is a separate battery-side alarm. Don't keep clearing any of them. Call an engineer.
See diagnostic guideMeter Lost Fault means the link between the meter and the inverter is interrupted. Code 240 means the CT or meter isn't detected, and a firmware mismatch after a battery change can cause it too. The meter and CT wiring is an engineer's job.
See diagnostic guideBattery stuck at a low state of charge. A battery may not charge because of the work mode or a schedule, a BMS communication alarm or a low battery level. The alarm in the FoxCloud 2.0 app or on the inverter screen shows which.
See diagnostic guideThe inverter shows a BMS Lost or Bms Ext Fault alarm (communication with the battery interrupted), and the battery stops charging and discharging. An ECS battery also shows communication-failed light patterns. If the alarm keeps coming back, the cause may be the cable or the battery. Call your installer or the battery supplier, or call us.
See diagnostic guideThe EPS backup output does not supply power during a grid outage. Backup needs an inverter with an EPS output, the protected circuits wired to it, EPS switched on in the inverter settings, and a battery charged above its off-grid minimum SOC setting. The wiring, earthing and EPS settings are an installer's job.
See diagnostic guideApp or Fox Cloud portal shows no data. Could be the datalogger (the device that links your system to Fox Cloud) losing its connection, a broadband failure, or an outage on Fox's side. The system usually keeps running while the app is offline, so check the inverter's own screen. Monitoring and app control, including settings changes, stop until it reconnects.
See diagnostic guideDatalogger unable to establish a WiFi connection. It usually needs re-pairing after a new router or a changed WiFi password. A WiFi dongle connects on the 2.4GHz band only. If it still won't connect, we set it up on site, from £195: we connect it to your WiFi, set up your router, including a separate 2.4 GHz network if it needs one, and check it's reporting.
See diagnostic guideFox ESS fault code index
Seeing an alarm in Fox Cloud or on the inverter? Our guide explains what the alarms mean and the safe next steps, by Fox's own alarm names.
Fault code categories
- Grid alarms: Grid Lost, Grid Volt and Grid Freq
- Battery communication & BMS errors: alarms for whichever Fox battery is fitted (EP, EQ, ECS and others)
- Insulation and earth alarms: Iso Fault (solar side), Ground Fault (earth), Bms Insul Fault (battery side)
- Voltage and current protection: Pv Volt Fault, the PV and battery current faults, DCI Fault
- Monitoring-related alarms: Meter Lost Fault and the BMS communication faults. A lost internet link shows as "offline" in the app.
- Book a Fox ESS diagnostic
What we do for Fox ESS owners
Remote Fox ESS Diagnostic
We review Fox Cloud data, inverter settings, and alarm history to identify the fault remotely.
- Alarm code root-cause analysis
- Fox Cloud data review
- Written engineer summary
Fox Cloud Portal Recovery
Portal access lost or monitoring never set up? We get access through an account transfer (£95) or your login, shared with your permission, and reconfigure the system.
- Account access recovery
- Settings reconfiguration
- On-site WiFi setup, from £195
On-Site Fox ESS Repair
BMS cable checks, grid settings if requested, EPS circuit checks and component replacement. A targeted visit, led by the evidence and quoted in writing before we start. For a warranty claim, if your Fox ESS installer has gone bust, we can be the Local Installer you appoint to make the claim.
- Evidence-led targeted checks
- Safety-focused report
- Repair or replacement path
Fox ESS datasheets and manuals
Datasheets, user manuals and quick installation guides for Fox ESS inverters and batteries. Self-hosted copies, kept as Fox ESS supplied them. Check Fox ESS for the newest issue.
- Product datasheets
- User and installation manuals
- Quick installation guides
- Fox ESS warranty: terms and who can claim
About Fox ESS systems: what you need to know
Fox ESS is a Chinese manufacturer. The H1 hybrid inverter series (single phase, 3 to 6kW in the UK) combines solar MPPT, battery management, and grid connection in one unit. Fox's three-phase range is the H3 series. The H1 pairs with Fox's high-voltage batteries: the current EP, EQ and CQ ranges, and the older ECS modules, which stack to add storage. The AC1 is an AC-coupled battery inverter in the same 3 to 6kW range as the H1. It has no solar input and is used to add a Fox battery beside an existing solar inverter.
The Fox Cloud portal and app provide monitoring and configuration. The inverter's country or grid-standard setting is made at commissioning. EPS (the backup output) needs the protected circuits wired to the EPS output and EPS switched on in the inverter settings, both by the installer. A BMS Lost or Bms Ext Fault alarm means the inverter has lost contact with the battery, and Fox's action for it is a check of the BMS cable, which is an installer's job.
We help with grid alarms (voltage, frequency or a lost supply), EPS wiring or settings (backup not working), BMS communication faults (the inverter has lost contact with the battery) and Fox Cloud connectivity (a lost datalogger connection or broadband loss). If you're searching for Fox ESS repair UK, Fox ESS battery not charging, Fox ESS grid code fault, Fox Cloud offline, or Fox ESS EPS not working, STS provides independent diagnostic and repair support across the UK. We're not affiliated with or endorsed by Fox ESS. We cover all Fox ESS models, current and older.
H1-G2 and AC1-G2, KH and KA, H3 Smart and H3 Pro inverters, the Evo and PowerQ (PQ1) all-in-ones, MiniQube, and EP, EQ and CQ batteries. The H3 Plus is a commercial range.
First-generation H1, AC1, H3 and AC3 inverters, and ECS and HV2600 batteries.
STS supports all major inverter and battery brands, not just Fox ESS. If you have a mixed-brand system or are comparing options, visit the brand hub.
More Fox ESS help
Fox ESS fault guides: battery not charging, BMS comms, grid faults, EPS backup, ground fault and Fox Cloud offline. Not affiliated with or endorsed by Fox ESS.
See Fox ESS problems & faultsFox ESS inverter and battery alarms by name: Grid Volt Fault, BMS Lost, Iso Fault and more. What each means, what Fox advises, and where app numbers come from.
See fault codesDownload Fox ESS datasheets and manuals for the H1 (G2), H3, EVO and the EP, EQ and ECS batteries, plus quick installation guides for the H3 and H3 Smart.
See documents & downloadsFox ESS UK warranty terms by product, the 120-day Fox Cloud rule and who can claim, from the 2026 policies. If your installer's gone bust, we can claim.
See Fox ESS warrantyFox ESS questions answered
Ready to fix your Fox ESS system?
Tell us what's happening. We'll review your details and come back with a clear diagnosis path, usually the same day.
- Not affiliated with or endorsed by Fox ESS
- No fix, no fee covers remote fixes. On-site work is quoted in writing before we start.
- On-site visits available
We’re busier than ever. Thank you for your patience.
Due to unprecedented demand we’re currently only carrying out on-site work in Yorkshire, and replies are taking up to 7 days. Remote diagnostics continue for the whole UK as normal.
Every message is read and answered, so please don’t send it twice; that only slows the queue.
We use cookies to measure traffic and ads, sharing limited hashed data with Meta and Google. Decline keeps only essential cookies. Privacy policy
Got a solar fault or need a quick answer? Drop us a message and we usually reply within a few minutes. Mon–Fri, 9am–7pm.