Growatt Fault Code Index
Every Growatt error code from the inverter display and ShineServer portal — what it means, the most likely cause, and what to do. Find your code in the index below or use the category sections to browse by system area.
Jump to category
If your Growatt inverter is showing a fault code and you need expert diagnosis, a remote diagnostic identifies the cause and recommends the fix — usually within 30 minutes.
Book Growatt diagnosis — £75 → How diagnostics workFault codes generated by the inverter in response to AC supply problems, DC overvoltage from panels, or temperature issues. These typically cause the inverter to stop generating.
Error 01
Grid over-voltage
Error 02
Grid under-voltage
Error 03
Grid over-frequency
Error 05
PV over-voltage
Error 07
Over-temperature
AFCI arc fault
⚠ Arc fault — newer models
Fault codes related to insulation resistance between the PV string and earth, or between AC wiring and earth. These are safety-critical faults.
Error 04
⚠ Insulation fault
Error 04 (AC side)
⚠ AC isolation fault
Fault codes related to grid supply, grid voltage, and grid current issues.
Error 08
AC over-current
Error 10
No grid
Error 21
Residual current fault
Grid under-frequency / Low frequency
Under-frequency disconnect
Fault codes from the battery management system — communication failures, voltage protection events, and thermal management.
Error 61
Battery comms fault
Error 62
Battery over-voltage
Error 63
Battery under-voltage
Error 71
Fan fault
Faults related to data communication between inverter and monitoring portal, and internal processor communication.
ARM-DSP comms fail
Internal processor fault
No data — portal offline
Monitoring connectivity
Growatt releases firmware updates that may introduce new fault codes. If your code isn't listed, share the exact code from your inverter display or ShineServer and we'll identify it.
Identifying the fault location: MC4 connectors, string cable, or panel junction box.
RS485 and CAN cable checks, power cycle sequence, and firmware mismatch diagnosis.
Full power cycle procedure, firmware re-flash, and board replacement indicators.
Growatt fault code questions
Growatt fault codes appear on the inverter's LCD screen as Error XX (e.g. Error 04). They are also logged in the ShineServer portal under Device > History, and in ShinePhone under the error history tab. Note the exact error number — including whether it is a warning or error — before contacting support or searching this index.
Error 04 is an insulation fault — the resistance between the PV string and earth has dropped below a safe threshold. This can indicate water ingress at MC4 connectors, damaged string cabling, or a faulty panel junction box. You should not touch any DC cabling. The system should be isolated at the consumer unit until an engineer has identified the fault source. Do not restart the system repeatedly — this does not fix the fault and may worsen the underlying issue.
The ARM-DSP fault indicates the inverter's two internal processors have lost communication. This is often caused by a firmware corruption or a transient startup fault — a full power cycle (turning off AC isolator, DC string isolator, and waiting 60 seconds before restarting) clears it in many cases. If it returns persistently, the inverter control board may need replacement or a firmware reflash by a qualified engineer.
Yes, the ShinePhone app and Growatt server log fault history that STS engineers can review. Remote diagnosis starts from £75, and many firmware-related faults can be resolved without a site visit.
Got a fault code and need it diagnosed?
Share the exact fault code from your inverter display or ShineServer, what the system is doing, and when it started. We'll identify the cause and tell you whether it needs a remote settings fix or a site visit.